
Specialised StructuresTo be confirmed
Project 2: Chimney Support Structure
APZEM
- Location
- Ahmedabad, Gujarat
- Footprint · height
- 1.44 m² · 13.5 m
View project
Division 01 · Service 02 of 12 · Frames · Trusses · Connections
Steel delivers high strength for its weight, long clear spans and fast, precise erection. Its performance depends on the stability of the frame and the design of every connection.

Engineering overview
Steel carries a great deal of load for its weight, so steel members are slender — and slender members fail by buckling long before the material itself is exhausted. Designing in steel is therefore largely a question of restraint: which way a member can move, what stops it, and whether the frame as a whole is stable.
The connections decide how the structure behaves. A bolted joint designed as a pin and the same joint designed to carry moment produce two different frames, with different member sizes, bracing and deflections. Connection design is part of the structural concept, not a detail left for later.
Steel is fabricated off site to tight tolerances and erected quickly, which suits long spans, industrial programmes and structures that must be added to or altered later.
01
Portal and braced frames
Rigid portal frames for clear spans and braced frames where bracing can be placed — each with its own stability strategy.
02
Roof and floor trusses
Trusses for long spans and heavy roofs, with members arranged so loads travel axially through the web.
03
Bolted and welded connections
Connections designed for the forces and behaviour the analysis assumes — pinned, moment-resisting or base fixity.
04
Platforms, galleries and supports
Access platforms, walkways and support steelwork for plant, equipment and services.

Connections
The same columns and rafters can form a stiff portal or a frame that relies entirely on bracing — the difference is in the connections. Haunches, end plates, bolt groups and base plates are therefore designed alongside the members, not after them.
Getting the joint right also determines fabrication cost: a connection that is easy to make and erect is part of an economical steel design.
Engineering considerations
01
Buckling and restraint
Compression members and compression flanges must be restrained against buckling. Purlins, girts and fly braces are structural members, not secondary afterthoughts.
02
Frame stability
Every frame needs a defined route for lateral load — rigid joints, bracing or a stiff core — in both directions and during erection.
03
Connection behaviour
Joint stiffness, bolt arrangement and weld design must match the assumptions of the analysis.
04
Serviceability
Deflection limits protect cladding and finishes; floors and platforms are also checked for vibration in use.
05
Corrosion and fire
Protection systems depend on the environment and on fire requirements, and affect both cost and maintenance.
06
Fabrication and erection
Member sizes, splices and connection types should suit fabrication, transport and the erection sequence.
Technical illustration
Wind on the side of a portal frame building is carried by the rigid frames across the building and by bracing along its length, down to the bases. Purlins and girts also restrain the frame members against buckling. Schematic only.

Structural systems
Portal frames
Rigid joints at eaves and apex give a clear span without internal bracing; frame sway and rafter stability govern.
Braced frames
Simple beam–column joints with diagonal bracing providing stability — economical where bracing does not obstruct use.
Trusses
Triangulated members carrying load in tension and compression, for long roof spans and heavy loads.
Lattice towers and support structures
Braced towers and frames supporting stacks, platforms and equipment, often governed by wind.
Explore in 3D
Rotate the model to follow the bracing, select a connection, or explode the frame into its members.

A generic teaching model — not a specific ARM Structures project.
Technical visual storytelling
Systems, details and building types this service addresses.



Conceptual illustrations — not photographs of ARM Structures projects.
Technical approach
Frame concept
Choose the frame type and stability system for the spans and use.
Bracing and restraint
Locate bracing and restraints in both directions.
Member design
Design columns, rafters, trusses and secondary members.
Connections
Design connections as first-class structural elements.
Applications
Industrial buildings
Clear-span production halls, warehouses and sheds.
Plant structures
Support steelwork for equipment, pipework and process plant.
Canopies and roofs
Open canopies and long-span roofs, where wind uplift often governs.
Towers and access structures
Chimney supports, maintenance towers and access platforms.
Concept to structure
ARM’s structural model of the steel chimney support structure for APZEM, beside a position for a photograph of the fabricated structure.
ARM structural model view
Project references

Specialised StructuresTo be confirmed
APZEM
View project

IndustrialUnder construction
AAVIN
View project
Deliverables
The deliverables for each commission are agreed with the client at the outset, according to the project’s stage and needs.

Reinforced concrete frames, slabs, walls and foundations.
Key elements: Beam–slab & flat slabsMoment framesShear walls

Analysis models, member design and structural drawings.
Key elements: Load analysisMember designDetailing

Division 02 · Advanced Systems
Economical long-span steel buildings with tapered frames.
Key elements: Tapered framesPurlins & girtsBracing
Start a conversation
Describe the span, use, loads and any cranes or equipment it must carry, and we’ll discuss the frame and stability system it needs.