Post-Tensioned Structural Systems

Post-tensioning pre-loads concrete with high-strength tendons, counteracting gravity to allow longer spans, thinner slabs and better control of deflection and cracking.

Post-tensioning tendons and anchorages at the edge of a concrete slab, with reinforcement on the deck above
Representative image Illustrative artwork — not a photograph of an ARM project.

Engineering overview

Concrete that is pre-loaded against its own weight.

In a post-tensioned slab, high-strength steel tendons are draped through the concrete in a curved profile and stressed after it has gained strength. Pulled tight, the curved tendon pushes upwards on the slab between supports — an internal load that counteracts much of the slab’s own weight.

Because part of the gravity load is balanced, slabs can be thinner and spans longer than in conventional reinforced concrete, with better control of deflection and cracking. That means lower building heights, fewer columns and more flexible floors.

The benefits come with design obligations of their own: concentrated anchorage forces, prestress losses, restraint to the slab’s shortening, and the need to keep a permanent record of where the tendons run.

Scope of services

  1. 01

    Post-tensioned flat slabs

    Flat slabs with tendons profiled between columns, for thin floors and clear soffits.

  2. 02

    Banded and distributed tendon layouts

    Tendons concentrated in bands over column lines in one direction and distributed in the other — or arranged to suit the floor plan.

  3. 03

    Transfer and long-span beams

    Post-tensioned beams carrying heavy loads over long spans or transferring columns.

Technical illustration

How a draped tendon lifts the slab

Stressed along a curved profile — high over supports, low at mid-span — a tendon exerts an upward pressure on the concrete that balances part of the slab’s weight. Anchorages at each end apply the force. Schematic only.

How a draped tendon lifts the slabSlab self-weight and imposed loadUpward pressure from the stressed, curved tendon balances part of the loadTendon low at mid-spanTendon high over the supportAnchorage — force enters the slab hereLive or dead end
Technical diagram

Engineering considerations

What the design has to resolve

  1. 01

    Load balancing

    The tendon profile and force are chosen to balance a chosen portion of the permanent load; the remainder is carried as in ordinary reinforced concrete.

  2. 02

    Prestress losses

    Friction, anchorage set, elastic shortening, creep, shrinkage and relaxation all reduce the tendon force over time and are allowed for in design.

  3. 03

    Anchorage zones

    Each anchorage applies a concentrated force to the slab edge; bursting and spalling reinforcement is needed to spread it safely.

  4. 04

    Restraint to shortening

    Prestress shortens the slab. Stiff walls and cores that resist this movement can crack or attract force, so their location and connections are planned with the tendons.

  5. 05

    Punching shear

    At columns the slab is checked for punching shear; tendons passing near the column help but do not remove the need for the check.

  6. 06

    Openings and future changes

    Tendon positions must be recorded and openings planned, because cutting a tendon later is a serious structural intervention.

Post-tensioning anchorages at a slab edgeConceptual illustration

Anchorages

Large forces, concentrated at the edge

All the prestress enters the slab through its anchorages. Behind each one the concrete must carry a concentrated force without splitting, which calls for carefully detailed bursting reinforcement and concrete that has reached the required strength before stressing.

Edge geometry, anchorage spacing and the stressing sequence are therefore designed together.

Conceptual 3D illustration for Post-Tensioned Structural SystemsConceptual illustration

Structural systems

Systems and where they apply

  1. 01

    Flat plates

    Uniform post-tensioned slabs on columns, with tendons in two directions.

  2. 02

    Banded slabs

    Wide, shallow beam bands with concentrated tendons, and thinner slabs between them.

  3. 03

    Post-tensioned beams

    Beams with draped tendons for long spans, car parks and transfer levels.

Explore in 3D

Tendons inside the slab

Open the model to see the tendon profiles and anchorages within the floor.

Conceptual model: Post-Tensioned Structural SystemsConceptual model

A generic teaching model — not a specific ARM Structures project.

Visual record

Post-tensioning tendons on chairs before concretingConceptual illustration
Tendon stressing at an anchorageConceptual illustration
Soffit of a post-tensioned slabConceptual illustration

Technical approach

How the work is carried out

  1. 01

    Floor layout

    Agree spans, slab type and the positions of openings and cores.

  2. 02

    Tendon layout

    Set tendon profiles and layouts to balance the permanent load.

  3. 03

    Staged effects

    Check the slab at transfer of prestress and at each stressing stage.

  4. 04

    Openings coordination

    Coordinate openings and services with the tendon layout.

Applications

Where this work is used

  • Commercial floors

    Office and retail floors where clear, column-free space has value.

  • Car parks

    Long spans between columns for parking and circulation.

  • Column-free spaces

    Halls and large rooms where intermediate columns are unwanted.

Project references

Project references are linked here only where a project’s verified description supports the connection to this service. ARM’s full portfolio of eighteen projects — industrial, commercial, residential and specialised structures — is on the projects page.

Browse all projects

Deliverables

What you receive

The deliverables for each commission are agreed with the client at the outset, according to the project’s stage and needs.

Start a conversation

Considering a post-tensioned floor?

Tell us the spans, floor use and any constraints on depth or openings, and we’ll discuss whether post-tensioning suits the project.