Service 05: Post-Tensioned Structural Systems
Thinner slabs and longer spans with stressed tendons.
Key elements: Flat slabsTendon layoutsLong-span beams
Division 02 · Service 04 of 12 · Tapered frames · Light-gauge secondary
Pre-engineered buildings use tapered built-up frames and light-gauge secondary members, putting steel where the forces are greatest for economical long-span enclosures.

Engineering overview
A pre-engineered building replaces rolled sections with frames built up from plate. The web depth can then follow the bending moment along the frame: deep at the eaves haunch, shallower towards mid-span and at the base. The result is a long-span frame with much less steel than a uniform section would need.
Light-gauge cold-formed purlins and girts carry the roof and wall sheeting to the frames and restrain their flanges. Because the whole building is light, wind uplift and stability — not gravity — often govern the design.
Standardised frames, bay spacings and secondary members make PEB fast to fabricate and erect, which is why it is widely used for warehouses, factories and logistics buildings.
01
Tapered primary frames
Built-up frames whose depth varies with the bending moment, for single and multiple spans.
02
Purlins, girts and sag rods
Cold-formed secondary framing that carries the cladding and restrains the primary frames.
03
Rod and portal bracing
Longitudinal stability through rod bracing or, where openings prevent it, portal bracing.
04
Crane and mezzanine provisions
Frames, brackets and floors designed for overhead cranes and mezzanine levels where required.
Technical illustration
Bending in a portal rafter is greatest at the eaves haunch and smaller towards mid-span, so the built-up section is deepest where the moment is largest. Purlins and girts restrain the frame and carry the sheeting. Schematic only.
Secondary framing
Purlins and girts are often treated as cladding supports, but in a PEB they also brace the main frames. Under wind uplift the bottom flange of the rafter goes into compression, and only the flange braces from the purlins stop it from buckling.
Sag rods and bridging keep the cold-formed sections themselves stable. Every one of these small members has a role in the overall stability of the building.


Structural systems
Clear-span frames
A single tapered frame across the full width — maximum flexibility of the floor.
Multi-span frames
Interior columns shorten the rafter span and reduce frame weight for very wide buildings.
Lean-to and extensions
Secondary bays attached to a main frame, often for offices or loading areas.
Crane-bearing PEB
Frames with brackets and runway beams for overhead cranes, with stiffer columns and bracing.
Explore in 3D
Switch layers to see the tapered frames, the purlins and girts, and the bracing that holds them in line.

A generic teaching model — not a specific ARM Structures project.
Engineering considerations
01
Wind uplift
Light roofs can be lifted by wind suction; purlins, connections and anchorage are checked for reversal of load.
02
Flange restraint
Under uplift the inner flange of the rafter goes into compression; flange braces from the purlins restrain it.
03
Secondary member stability
Cold-formed purlins and girts rely on sag rods, bridging and the sheeting for their stability.
04
Anchorage and base fixity
Base conditions — pinned or fixed — change frame weight and foundation design and must be agreed between both.
05
Openings and bracing
Large doors can interrupt the bracing line; portal bracing provides stability where rods cannot go.
06
Future loads
Cranes, mezzanines, solar panels or services added later are far easier to accommodate if they are designed in from the start.
Technical visual storytelling
Systems, details and building types this service addresses.



Conceptual illustrations — not photographs of ARM Structures projects.
Technical approach
Frame and bay layout
Set the spans, bay spacing and eave height for the building’s use.
Primary frames
Design the tapered frames for the governing load combinations.
Secondary framing and bracing
Design purlins, girts, sag rods and bracing.
Anchorage
Design base connections and the anchorage into the foundations.
Applications
Warehouses
Large clear floors for storage and racking.
Factory sheds
Production buildings, with cranes or mezzanines where needed.
Logistics and storage buildings
Fast-track enclosures for distribution and storage.
Project references
Project references are linked here only where a project’s verified description supports the connection to this service. ARM’s full portfolio of eighteen projects — industrial, commercial, residential and specialised structures — is on the projects page.
Browse all projectsDeliverables
The deliverables for each commission are agreed with the client at the outset, according to the project’s stage and needs.

Thinner slabs and longer spans with stressed tendons.
Key elements: Flat slabsTendon layoutsLong-span beams

Factory-cast elements designed for lifting and connection.
Key elements: Precast elementsHollow-core unitsCorbel connections

Concrete and steel combined, each where it works best.
Key elements: RCC coresSteel floors & roofsEmbeds
Start a conversation