Service 08: Industrial Structural Engineering
Facilities, crane structures and equipment support.
Key elements: Crane girdersProcess platformsEquipment bases
Division 03 · Service 09 of 12 · Where every load path ends
Every load in a structure ends in the ground. Foundations spread those loads into the soil safely, and substructures resist the earth and water pressures around them.

Engineering overview
Foundations take every load the structure collects — its own weight, its contents, wind and earthquake actions — and pass it into soil or rock that can carry it without failing or settling too much. Their design starts not with the building but with the ground beneath it.
Two questions govern: can the ground carry the pressure, and how much will it settle? Uniform settlement is usually tolerable; differential settlement between adjacent foundations is what cracks floors and frames. The foundation type — pads, strips, a raft or piles — follows from the answers.
Substructures add earth and water pressure to the problem. Retaining walls and basements must resist the ground pushing on them and, below the water table, the water pushing up.
01
Isolated, combined and strip footings
Shallow foundations sized for the column and wall loads and the ground’s capacity.
02
Raft foundations
A single slab under the building where loads are heavy or the ground is weak or variable.
03
Pile foundations and pile caps
Piles carrying load to deeper, stronger strata, with caps that distribute column loads to them.
04
Plinth beams, retaining walls and basements
Ground-level ties and below-ground structures resisting soil and water pressure.
05
Equipment and machine foundations
Foundations for plant and machinery, including their operating loads.

Ground first
Two buildings with identical loads can need entirely different foundations if one sits on dense sand and the other on soft clay over rock. That is why foundation design begins with the site’s ground information: borehole logs, soil strengths, the water table.
Where that information is incomplete, the right answer is usually more investigation — not more concrete.
Technical illustration
Pads and strips spread load into firm ground near the surface; a raft spreads it over the whole footprint; piles carry it down to a stronger stratum. The choice follows from the loads and the ground investigation. Schematic only.

Structural systems
Isolated and combined footings
Individual pads under columns, combined where columns are close or near a boundary.
Strip footings
Continuous footings under walls or closely spaced columns.
Rafts
One slab spreading the whole building load — reducing pressure and evening out settlement.
Piles
Load transferred to depth through end bearing, shaft friction or both.
Explore in 3D
Rotate the model to compare isolated footings, rafts and piles, and how each spreads load into the ground.

A generic teaching model — not a specific ARM Structures project.
Engineering considerations
01
Ground information
Foundation design depends on the site’s ground investigation; the type, depth and size are chosen to suit the soil it reports.
02
Bearing and settlement
Allowable pressure keeps the ground from failing; settlement limits — especially differential settlement — protect the structure above.
03
Groundwater
A high water table affects excavation, uplift on basements and the durability of buried concrete.
04
Neighbouring structures
Excavation and new loads near existing buildings must not undermine or overload their foundations.
05
Aggressive ground
Sulphates, chlorides and other chemicals in soil or groundwater influence concrete specification and cover.
06
Dynamic loads
Machine foundations are designed for vibration as well as weight, and are usually separated from adjacent slabs.
Technical visual storytelling
Systems, details and building types this service addresses.



Conceptual illustrations — not photographs of ARM Structures projects.
Technical approach
Ground information
Review the site’s ground investigation and loads from the structure.
Foundation type
Choose the foundation type and depth to suit the loads and the soil.
Sizing and design
Size and design foundations and substructure elements.
Substructure
Design plinth beams, retaining walls and basements.
Applications
New buildings
Foundations for residential, commercial and industrial buildings.
Industrial plant and equipment
Foundations for heavy and vibrating equipment.
Sites with variable ground
Where soil conditions change across the site or with depth.
Project references
Project references are linked here only where a project’s verified description supports the connection to this service. ARM’s full portfolio of eighteen projects — industrial, commercial, residential and specialised structures — is on the projects page.
Browse all projectsDeliverables
The deliverables for each commission are agreed with the client at the outset, according to the project’s stage and needs.

Facilities, crane structures and equipment support.
Key elements: Crane girdersProcess platformsEquipment bases

Division 04 · Built Environment & Advisory
Assessment of a building’s construction and condition for valuation.
Key elements: InspectionConditionValuation report

Division 04 · Built Environment & Advisory
Planning, design and drawings, coordinated with the structure.
Key elements: Space planning3D visualisationDrawings
Start a conversation
Share the building loads and any ground investigation for the site, and we’ll discuss the foundation type it points to.